
Your Custom Quiz
In Violini 2024 et al., on 3D-guided spinal stabilization in brachycephalic dogs, what postoperative complication occurred due to PMMA cement overextension?
🔍 Key Findings
- Spinal stabilization with 3D-printed patient-specific drill guides (3D-PSGs) was safe, with no immediate perioperative complications reported.
- 84% of pedicle screws were optimally placed, and only 0.5% breached the spinal canal, reflecting high placement accuracy.
- 80% of dogs experienced no neurologic deterioration postoperatively, indicating reliable short-term safety.
- 3D-PSGs were accurate and reproducible, even across multiple institutions and surgeons.
- Mid-term outcomes were favorable: all dogs were ambulatory, and 90% had static or improved neurologic signs.
- 7 of 10 mid-term follow-ups showed abnormal gait, though owners rated lifestyle ≥3/5, suggesting acceptable function.
- 3D-printed guides enabled precise pedicle screw placement in deformed vertebrae, expanding options in small breeds.
- One dog suffered a T4 spinous process fracture due to overextension of PMMA cement, emphasizing the need for cement placement caution.
Veterinary Surgery
4
2024
Clinical outcomes of 20 brachycephalic dogs with thoracolumbar spinal deformities causing neurological signs treated with spinal stabilization using 3D-printed patient-specific drill guides
2024-4-VS-violini-3
In Monnet 2023 et al., on barbed vs conventional suture in vesicourethral anastomosis (VUA), what was the median suturing time for the unidirectional barbed suture group (UBS)?
🔍 Key Findings
- Leakage pressure was not significantly different between unidirectional barbed suture (UBS) and conventional (C) suture groups (p = .236).
- UBS group had a 28% lower median leakage pressure than the C group (8.6 mmHg vs. 11.7 mmHg), suggesting higher biological risk of leakage.
- UBS significantly reduced suturing time (median 12.7 vs. 17.3 minutes; p < .0002).
- Fewer suture bites were needed in the UBS group (median 14 vs. 19; p = .012).
- No suture breakage or urethral narrowing occurred in either group.
- Leakage site distribution (ventral vs lateral) was similar between groups; no dorsal leaks noted.
- Leakage occurred as low as 5 mmHg in UBS group, indicating potential for postoperative extravasation.
- UBS may aid intracorporeal suturing in minimally invasive prostatectomy, but catheterization remains necessary postoperatively.
Veterinary Surgery
5
2023
Influence of conventional versus unidirectional barbed suture on leakage pressures in canine vesicourethral anastomosis: An ex-vivo study
2023-5-VS-monnet-2
In Cruciani 2022 et al., on feline pancreaticoduodenostomy, which postoperative finding was observed and monitored without clinical consequence?
🔍 Key Findings
- Left pancreaticoduodenostomy successfully restored digestive continuity after right lobe and body pancreatectomy in a cat.
- No clinical signs of exocrine or endocrine insufficiency were observed postoperatively up to 225 days.
- Histopathology confirmed chronic pancreatitis with abscess formation and reactive lymphadenopathy.
- No postoperative pancreatitis developed, based on imaging and normal feline pancreatic lipase levels.
- Progressive focal ampulla-like dilation of the pancreatic duct occurred near the anastomosis without clinical signs.
- The cat maintained weight and improved clinically for several months post-op, indicating satisfactory outcomes.
- Surgical technique involved end-to-side anastomosis between the left pancreatic duct and duodenum.
- Ultimately, the cat was euthanized due to disseminated carcinoma, presumed unrelated to the pancreatic surgery.
Veterinary Surgery
8
2022
Left pancreaticoduodenostomy after removal of the right lobe and the head of the pancreas in a cat
2022-8-VS-cruciani-2
In Jones 2024 et al., on surgical technique mortality, what possible reason was proposed for increased mortality with BVSD?
🔍 Key Findings
- Study compared 606 dogs (English Bulldogs, French Bulldogs, Pugs) undergoing partial staphylectomy via CO₂ laser, bipolar vessel sealing device (BVSD), or conventional incision.
- Mortality rate: 4.0% (24/606).
- BVSD was associated with significantly increased perioperative mortality compared to other methods (OR = 6.0, 95% CI: 1.3–28.4, p = .023).
- High-grade laryngeal collapse (stage II or III) independently increased mortality risk (OR = 4.6, 95% CI: 1.8–11.8, p = .002).
- No difference in mortality between CO₂ laser and conventional incision techniques.
- CO₂ laser and conventional techniques had similar complication rates.
Veterinary Surgery
1
2024
Comparison of mortality of brachycephalic dogs undergoing partial staphylectomy using conventional incisional, carbon dioxide laser, or bipolar vessel sealing device
2024-1-VS-jones-5
In Kurogochi 2025 et al., on cardioplegia in mitral repair, what was concluded about long-term outcomes between groups?
🔍 Key Findings
- No significant difference in cardiac troponin I levels 12h post-op between mDN and St. Thomas cardioplegia groups (p = 0.478)
- Sinus rhythm returned faster in the mDN group after aortic cross-clamp removal (median 60s vs 362s, p = 0.027)
- Lower serum potassium at cross-clamp removal in the mDN group (median 4.5 mEq/L vs 5.4, p = 0.005)
- Fewer doses needed in the mDN group (median 2.5 vs 4.0, p = 0.040)
- Higher total crystalloid volume used in mDN group (23.6 vs 12.6 mL/kg, p < 0.001)
- No difference in survival (700-day survival 90% in both groups, p = 0.958)
- No difference in hospitalization duration (median 6 days for both, p = 0.789)
- Echocardiographic remodeling similar between groups at 24h post-op
Veterinary Surgery
7
2025
Saline‐based modified del Nido cardioplegia versus multidose St. Thomas cardioplegia in canine mitral valve repair: A randomized controlled trial
2025-7-VS-kurogochi-5
In Bergen 2024 et al., on biliary stent use, what material was used for most BEMBS?
🔍 Key Findings Summary
- Subjects: 11 animals (8 dogs, 3 cats)
- Technique: Uncovered balloon-expandable metallic biliary stents (BEMBS)
- Indications: Cholelithiasis, strictures, neoplasia, cholangiohepatitis, etc.
- Success: Patency achieved in all animals surviving to discharge
- Complications:
- Short-term mortality: 2/11 (1 euthanized for SIRS, 1 unknown)
- Long-term issues: cholangiohepatitis, choledocholithiasis, stent occlusion (in cats only)
- Long-term patency:
- Dogs: median 650.5 days
- Cats: median 446 days
- Stent removal possible even after >600 days in some cats
- Clinical outcome: Viable alternative to plastic stents or cholecystoenterostomy
Veterinary Surgery
2
2024
Clinical use of uncovered balloon‐expandable metallic biliary stents for treatment of extrahepatic biliary tract obstructions in cats and dogs: 11 cases (2012–2022)
2024-2-VS-bergen-2
In Lomas 2025 et al., on DPO and dorsolateral subluxation, what percentage of hips had a post-DPO DLS score <55%, indicating higher OA risk?
🔍 Key Findings
- DPO significantly improved femoral head coverage, increasing mean DLS from 36.1% to 71.4% postoperatively (p < 0.001).
- No significant change in DLS between immediate postoperative and follow-up scans, suggesting stable surgical outcomes over time.
- Greater plate angle (30°) yielded larger DLS improvement (mean increase: 39.8%) compared to 25° and 20° plates.
- Only 3 hips had post-op DLS scores <55%, indicating most patients had lower risk of osteoarthritis progression.
- No correlation found between DLS improvement and age, body weight, or side of surgery, suggesting broad applicability.
- CT was used for DLS measurement in simulated weight-bearing, improving precision over radiographic methods.
- Major limitations included small sample size, multiple surgeons, and variable sedation vs anesthesia during imaging.
- DPO confirmed as effective for reducing dorsolateral subluxation, improving coxofemoral joint congruency in dysplastic dogs.
Veterinary and Comparative Orthopaedics and Traumatology
2
2025
The Impact of Double Pelvic Osteotomy on Dorsolateral Subluxation in 24 Dogs
2025-2-VCOT-lomas-4
In Ellis 2024 et al., what was the purpose of using standardized CT reconstruction planes?
🔍 Key Findings Summary
- 86 elbows assessed: 32 Guide Dogs, 11 Border Collies
- Guide Dogs showed significantly higher HU values in:
- MCP: min (p = 0.022), mean (p < 0.01), max (p < 0.01)
- Humeral trochlea: mean (p < 0.01), max (p < 0.01)
- Results imply breed-associated HU variation, not necessarily pathologic sclerosis
- Relevance: Important to avoid false positives for elbow dysplasia during CT-based breeding screens
- Good interobserver agreement for mean HU values (ICC ~0.82–0.90)
Veterinary and Comparative Orthopedics and Traumatology
3
2024
Comparison of Hounsfield Units within the Humeral Trochlea and Medial Coronoid Process in a Population of Labrador X Golden Retriever Guide Dogs and Border Collies
2024-3-VCOT-ellis-3
In Papacella-Beugger 2024 et al., what issue led to three screws being poorly positioned?
🔍 Key Findings Summary
- Cadaveric study using 3 miniature breed dogs (6 hemipelves) to assess spinal neuronavigation accuracy for lumbar plate fixation
- 20 screws placed using CBCT-based navigation with real-time tracking
- 85% (17/20) of screws were safely and accurately placed
- Median deviation of screw entry points from plan: 1.8 mm
- All 3 misplaced screws occurred in a single cadaver, attributed to inexperienced drill handling
- Custom 3D-printed lightweight tracking array was necessary due to small spinous processes in miniature dogs
- No iatrogenic canal perforations or vertebral damage in any specimen
- Concludes neuronavigation offers precise, safe placement of spinal implants in small dogs, with minimal anatomic disruption
Veterinary and Comparative Orthopedics and Traumatology
6
2024
Spinal Neuronavigation for Lumbar Plate Fixation in Miniature Breed Dogs
2024-6-VCOT-papacella-beugger-3
In Payne 2024 et al., on HIF propagation pattern, what was the approximate rate of isthmus diameter increase per kilogram of body weight?
🔍 Key Findings Summary
- HIF typically originates 57° caudal to the supratrochlear foramen and propagates cranially in a segmental pattern.
- %HIF correlated significantly with both fissure depth and length:
- %DHIF increased linearly (r = 0.989, p < 0.001)
- %LHIF followed a sigmoidal relationship with %HIF (p < 0.001)
- Higher %HIF was significantly associated with:
- Clinical lameness (p = 0.004)
- Distal shift in the fissure center (CHIF)
- Implant complications in 5/17 elbows treated with transcondylar screws
- Isthmus diameter increased with weight (p = 0.002), relevant for screw sizing
Veterinary and Comparative Orthopedics and Traumatology
2
2024
Computed Tomography Topographical Analysis of Incomplete Humeral Intracondylar Fissures in English Springer Spaniel Dogs
2024-2-VCOT-payne-5
Quiz Results
You answered 7 out of 10 questions correctly
Key Findings
