In Deprey 2022 et al., on gap fracture implants, which construct had significantly lower axial deformation in compression testing?
🔍 Key Findings
- NAS-ILN had significantly greater stiffness in both axial compression and 4-point bending compared to LCP constructs.
- Ultimate load to failure was significantly higher for NAS-ILN in compression (804 N vs 328 N) and bending (25.7 Nm vs 16.3 Nm).
- Torsional stiffness and angular deformation were similar, but NAS-ILN resisted higher torque to failure than LCP (22.5 Nm vs 19.1 Nm).
- No slack was observed with the NAS-ILN construct, unlike older nail designs.
- Failure modes differed: LCPs failed via plate bending; NAS-ILNs failed at the implant or bone near screw holes.
- Titanium alloy and curved design of NAS-ILN provides better anatomic fit and more uniform stress distribution.
- A third, perpendicular locking hole in NAS-ILN may enhance torsional stability but was not utilized in this study.
- The curved, angle-stable design of NAS-ILN is a novel advancement in veterinary orthopedics.
Veterinary Surgery
8
2022
Mechanical evaluation of a novel angle‐stable interlocking nail in a gap fracture model
2022-8-VS-deprey-1
In Takagi 2022 et al., on hepatic venous anatomy, which liver lobe consistently showed a single hepatic vein draining into the caudal vena cava or via the left hepatic vein?
🔍 Key Findings
- Hepatic venous drainage patterns vary widely across all lobes, especially the left lateral lobe.
- Right lateral lobe had a median of 2 vessels draining directly into the caudal vena cava (CVC); range: 1–4.
- Caudate process of caudate lobe had the most variability: 1–5 vessels draining into the CVC; 2 vessels was most common (54.5%).
- Left lateral lobe drained via 2–8 veins into the left hepatic vein (LHV), with 3 veins most common (31.2%).
- Left medial lobe typically had 1 vein draining into the LHV (61% of dogs).
- Papillary process drained into the LHV in 93.5% of cases; 6.5% drained directly to the CVC.
- Quadrate lobe always had 1 vessel draining either directly to the CVC or via the LHV.
- CTA revealed more variations than previously described in plastinated or cadaveric studies, highlighting its superior value in surgical planning.
Veterinary Surgery
4
2022
Computed angiographic variations in hepatic venous vasculature in dogs
2022-4-VS-takagi-1
In Veytsman 2023 et al., on feline insulinoma outcomes, what was the median disease-free interval (DFI) in cats without metastasis?
🔍 Key Findings
- Surgical excision of insulinomas resulted in euglycemia or hyperglycemia in 90% of cats immediately post-op.
- 18/20 cats (90%) survived to hospital discharge, with a median survival time of 863 days.
- Younger age, metastasis at surgery, tumor invasion, and lower glucose levels were negative prognostic factors.
- Two cats had stage III disease with metastasis; one lived 413 days post-op, suggesting some benefit to surgery even in advanced disease.
- Postoperative hypoglycemia and seizure activity were associated with poorer outcomes; one cat euthanized due to seizures despite euglycemia.
- Median disease-free interval (DFI) was 1052 days; for cats with metastasis, DFI dropped to 93 days.
- Partial pancreatectomy was performed in 11 cats, nodulectomy in 10, and enucleation in 1; method of resection not linked to outcome.
- Postoperative complications occurred in 25% of cats; most were manageable with supportive care.
Veterinary Surgery
1
2023
Retrospective study of 20 cats surgically treated for insulinoma
2023-1-VS-veytsman-5
In Neal 2023 et al., on transcondylar screw placement, what was the observed rate of joint infringement when using the aiming device?
🔍 Key Findings
- Aiming device provided comparable trajectory accuracy to fluoroscopy, especially in right limbs (1.9° vs. 3.4°, p = .0128).
- Eccentricity (deviation from condylar center) was lower with fluoroscopy (3.1 mm vs 4.2 mm, p = .0017), making fluoroscopy more precise.
- Odds of joint infringement were 8× higher with the aiming device, though not statistically significant (p = .0575).
- Residents had greater screw trajectory deviation than diplomates (p = .0366), highlighting impact of experience.
- Aiming device procedures took less time than fluoroscopy in some scenarios, particularly for right limbs with right-handed surgeons.
- Fluoroscopic procedures had more pin/drill attempts, increasing risk of glove puncture and potential aseptic breaks.
- Mean deviation angles in both groups (<3.5°) were within acceptable range to avoid intracondylar fracture gap.
- Cadaver model used large-breed, healthy adult dogs, not small-breed immature dogs, limiting generalizability.
Veterinary Surgery
4
2023
The effect of an aiming device on the accuracy of humeral transcondylar screw placement
2023-4-VS-neal-3
In Drudi 2022 et al., on CAL vs TAL outcomes, what clinical difference was reported between the two groups at 15-day follow-up?
🔍 Key Findings
- Cricoarytenoid lateralization (CAL) resulted in a significantly greater increase in rima glottidis area at both immediate (205%) and 15-day (199%) time points compared to thyroarytenoid lateralization (TAL) (152% and 127%, respectively).
- TAL group showed a significant reduction in rima glottidis area between immediate and 15-day postoperative measurements (P < .05), while CAL group had no significant reduction over time.
- No dogs in either group showed postoperative complications, including aspiration pneumonia, at the 15-day follow-up.
- All dogs showed improved clinical signs, including decreased stridor and increased exercise tolerance by day 15.
- CAL produced more stable postoperative glottic area, potentially due to preserved anatomical tension, whereas TAL might experience tension loss due to thyroid cartilage repositioning.
- Both procedures were technically effective and performed under the same protocol by a single board-certified surgeon.
- Endoscopic image analysis was used to quantify rima glottidis area, demonstrating a reliable objective method for surgical outcome assessment.
- Clinical outcome did not differ between groups, despite CAL showing a larger rima glottidis area.
Veterinary Surgery
3
2022
Comparison of immediate and short‐term outcomes of cricoarytenoid and thyroarytenoid lateralization in dogs with idiopathic laryngeal paralysis
2022-3-VS-drudi-4
In Matz 2022 et al., on stapler size comparison, what is the clinical significance of the finding that all stapler groups had ILPs exceeding 25 mmHg?
🔍 Key Findings
- No significant difference in initial leak pressure (ILP) among TA 30 V3 2.5 mm, TA 60 3.5 mm, and TA 60 4.8 mm stapler sizes (P = .78).
- All stapler types exceeded the physiological intraluminal pressure threshold (~25 mmHg), suggesting acceptable leak resistance.
- Mean ILPs: TA 30 V3 (181.5 mmHg), TA 60 3.5 mm (112 mmHg), TA 60 4.8 mm (77.2 mmHg).
- Leakage occurred at the staple line in 23 of 24 specimens; only one had ileal wall rupture.
- No correlation found between ILP and cadaver weight, cecal wall thickness, or cecal length.
- Cecal wall thickness averaged 4.9 mm, yet staple heights ranged only from 1.0–2.0 mm.
- One specimen in each TA 60 group leaked near or below physiologic pressures, suggesting rare outliers.
- Study supports clinical viability of all tested stapler sizes for canine typhlectomy, but highlights need for in vivo data on healing and complications.
Veterinary Surgery
4
2022
Ex vivo comparison of different thoracoabdominal stapler sizes for typhlectomy in canine cadavers
2022-4-VS-matz-4
In Schmutterer 2024 et al., what was the trend in mean pressure on the medial meniscus across all angles tested?
🔍 Key Findings Summary
- Biomechanical study on 14 hindlimbs from Retrievers (cadaveric)
- Three stifle flexion angles tested: 125°, 135°, and 145°
- Contact Force Ratio (CFR) was significantly higher at 125° and 135° than at 145° (p < 0.001)
- Center of force shifted caudally with increasing flexion — especially in medial meniscus
- Lateral meniscus peak pressure was significantly higher at 125° than 145° (p = 0.049)
- Mean pressures on lateral meniscus decreased with extension, while medial meniscus pressure remained constant
- Relevance: Helps interpret meniscal load in early cruciate disease and in surgical modeling
Veterinary and Comparative Orthopedics and Traumatology
3
2024
Evaluation of Meniscal Load and Load Distribution in the Sound Canine Stifle at Different Angles of Flexion
2024-3-VCOT-schmutterer-4
In Butare-Smith 2022 et al., on cerclage knot biomechanics, what was the typical failure mode of the twist cerclage under cyclic loading?
🔍 Key Findings
- Double-loop cerclage resisted the highest peak load (805 N) and maintained tension longer than twist (488 N) and single-loop (397 N) configurations.
- Double-loop cerclage sustained 500,000 cycles at 60–80% of peak load in some cases without loosening, outperforming other types.
- Twist knots loosened rapidly, often within 10 cycles even at low loads (100–390 N).
- Single-loop knots performed better than twist, with partial resistance up to 100,000 cycles at 160 N, but showed wide variability.
- All loosening occurred before wire breakage, indicating clinical failure would happen from slack, not fracture.
- Double-loop cerclage had highest initial tension (323 N) compared to single-loop (124 N) and twist (69 N).
- Fatigue limit was not identified for twist, since they all loosened early at even 20% of peak load.
- Clinical recommendation: double-loop cerclage is best for resisting repeated subfailure loading, ideal for fissure prevention or fragment stabilization.
Veterinary Surgery
2
2022
Double-loop cerclage resists greater loads for more cycles than twist and single-loop cerclage
2022-2-VS-butare-smith-2
In Miller 2024 et al., on SOP-LC mechanical testing, what was the impact of rod contouring on four-point bending strength?
🔍 Key Findings Summary
- No significant difference in mechanical properties between contoured vs non-contoured SOP-LC rods
- Clamp configuration significantly influenced mechanical performance:
- Single-side clamps → ↑ yield load, ↑ displacement, ↑ bending strength (p < 0.05)
- Alternating-side clamps → ↑ initial torsional stiffness (p = 0.029)
- Clamp slippage was evident only in torsional tests; screw loosening may be torque-dependent
- Mild screw bending and construct offset suggest subtle instability
- Recommends clamp configuration choice based on loading scenario
- Suggests 3.0 Nm torque may be more effective than 2.5 Nm to prevent clamp slippage
Veterinary and Comparative Orthopedics and Traumatology
4
2024
Mechanical Testing of Sliding on Pivot-Locking Clamp (SOP-LC) Fracture Repair System in Four-Point Bending and Torsion
2024-4-VCOT-miller-1
In Kokkinos 2025 et al., on THR age effects, which variable remained significantly associated with complications on multivariable analysis?
🔍 Key Findings
- Study population: 116 dogs underwent cementless THR; grouped by age:
- Group A: ≤6 months (n = 27)
- Group B: >6 to ≤12 months (n = 41)
- Group C: >12 months (n = 48)
- Overall perioperative complication rate: 31.9% (37/116)
- Group A: 22.2%
- Group B: 26.8%
- Group C: 41.7%
- No significant difference in total complication rate by age (p = .207), though older dogs (Group C) had numerically higher rates.
- Luxation was significantly more common in dogs >12 months:
- Group C: 14.6% vs. Group A (0%) and Group B (2.4%) → p = .049
- Most common complications: luxation (9.5%) and intraoperative fissure or fracture (9.5%)
- Time under anesthesia and surgery duration were not associated with complication risk (p = .297 and p = .781)
- No infections or aseptic loosening observed during the 8-week follow-up.
Veterinary Surgery
3
2025
The influence of age at total hip replacement on perioperative complications in dogs
2025-3-VS-kokkinos-3
Quiz Results
You answered 7 out of 10 questions correctly
Key Findings