Your Custom Quiz

In Neal 2023 et al., on transcondylar screw placement, which variable significantly influenced screw trajectory deviation regardless of method used?

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Correct. Residents had significantly more deviation (3.4° vs 2.5°) than diplomates, p = .0366.
Incorrect. The correct answer is Surgeon experience.
Residents had significantly more deviation (3.4° vs 2.5°) than diplomates, p = .0366.

🔍 Key Findings

  • Aiming device provided comparable trajectory accuracy to fluoroscopy, especially in right limbs (1.9° vs. 3.4°, p = .0128).
  • Eccentricity (deviation from condylar center) was lower with fluoroscopy (3.1 mm vs 4.2 mm, p = .0017), making fluoroscopy more precise.
  • Odds of joint infringement were 8× higher with the aiming device, though not statistically significant (p = .0575).
  • Residents had greater screw trajectory deviation than diplomates (p = .0366), highlighting impact of experience.
  • Aiming device procedures took less time than fluoroscopy in some scenarios, particularly for right limbs with right-handed surgeons.
  • Fluoroscopic procedures had more pin/drill attempts, increasing risk of glove puncture and potential aseptic breaks.
  • Mean deviation angles in both groups (<3.5°) were within acceptable range to avoid intracondylar fracture gap.
  • Cadaver model used large-breed, healthy adult dogs, not small-breed immature dogs, limiting generalizability.

Neal

Veterinary Surgery

4

2023

The effect of an aiming device on the accuracy of humeral transcondylar screw placement

2023-4-VS-neal-4

Article Title: The effect of an aiming device on the accuracy of humeral transcondylar screw placement

Journal: Veterinary Surgery

In Cola 2024 et al., on laparotomy-assisted endoscopy, which of the following foreign body characteristics significantly affected the success of LAER?

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Correct. Neither sharpness, number, nor location significantly affected LAER success.
Incorrect. The correct answer is None of the above.
Neither sharpness, number, nor location significantly affected LAER success.

🔍 Key Findings

  • LAER was effective (partial or complete) in 35/40 cases, regardless of FB location or type.
  • Intestinal wall damage significantly increased the likelihood of conversion to enterotomy (p = .043).
  • LAER led to significantly shorter hospitalization (median 48 h vs 72 h; p = .006).
  • Patients in the LAER group required less postoperative analgesia (median 36 h vs 48 h; p < .001).
  • Faster return to spontaneous feeding was seen in LAER group (median 24 h vs 36 h; p = .012).
  • No significant difference in complication rate or postoperative ileus between LAER and enterotomy groups.
  • Sharp, linear, or multiple FBs did not significantly affect LAER effectiveness.
  • Conversion to surgery was required in 5/40 LAER attempts, mostly due to immovable FBs or intestinal damage.

Cola

Veterinary Surgery

7

2024

Laparotomy‐assisted endoscopic removal of gastrointestinal foreign bodies: Evaluation of this technique and postoperative recovery in dogs and cats

2024-7-VS-cola-5

Article Title: Laparotomy‐assisted endoscopic removal of gastrointestinal foreign bodies: Evaluation of this technique and postoperative recovery in dogs and cats

Journal: Veterinary Surgery

In Ritson 2025 et al., on feline hilar lobectomy sealants, how were devices evaluated for seal integrity?

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Correct. Bronchial stumps were tested with increasing pressures in submerged cyclic ventilation simulation.
Incorrect. The correct answer is Leakage under cyclical positive pressure ventilation.
Bronchial stumps were tested with increasing pressures in submerged cyclic ventilation simulation.

🔍 Key Findings

  • No leakage occurred using pretied ligature loops (PLL) or double-shank (DS) titanium clips up to 40 cm H₂O airway pressure.
  • 1/10 stapled lobes leaked at supraphysiologic pressure (40 cm H₂O), but this was not statistically significant (p = .33).
  • All techniques sealed effectively under physiologic and supraphysiologic pressures in cadaveric feline lungs.
  • PLL and DS clips required less working space than staplers, making them more practical for small thoracic cavities.
  • DS titanium clips offer enhanced security due to dual shanks and tissue-gripping design, reducing clip slippage.
  • Leak testing was cyclic and submerged, simulating physiologic ventilation and allowing robust evaluation.
  • Stapling failure occurred along the staple line, highlighting risks of air leakage due to staple misalignment or poor hilar access.
  • PLL and DS clips may be cost-effective and efficient alternatives for open or minimally invasive feline lung lobectomy.

Ritson

Veterinary Surgery

7

2025

Ex vivo comparative evaluation of feline hilar lung lobectomy using linear stapler, pretied ligature loop, and double-shank titanium clips

2025-7-VS-ritson-4

Article Title: Ex vivo comparative evaluation of feline hilar lung lobectomy using linear stapler, pretied ligature loop, and double-shank titanium clips

Journal: Veterinary Surgery

In Longo 2025 et al., on MITA, what percentage of dogs achieved complete osseous union?

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Correct. Complete osseous union occurred in 46% of cases.
Incorrect. The correct answer is 46%.
Complete osseous union occurred in 46% of cases.

🔍 Key Findings

  • 15 dogs underwent minimally invasive tarsal arthrodesis (MITA); 10 partial, 5 pantarsal.
  • Mean time to radiographic union: 1.8 ± 0.5 months.
  • Mean time to clinical union: 3.7 ± 0.8 months.
  • Complete osseous union: 46%; the rest achieved ≥50% with functional weightbearing.
  • Complication rate: 26% major (mostly implant-related); no catastrophic complications or plantar necrosis.
  • Functional outcomes: 6 full, 8 acceptable, 1 unacceptable (not due to MITA).
  • MITA may lower soft tissue complications vs open approaches and enable faster healing.

Longo

Veterinary Surgery

1

2025

Minimally invasive tarsal arthrodesis in 15 dogs

2025-1-VS-longo-2

Article Title: Minimally invasive tarsal arthrodesis in 15 dogs

Journal: Veterinary Surgery

In Burton 2025 et al., on antebrachial conformation, what statistical result supported intraobserver reliability of PRUDA and UCORA?

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Correct. ICC values were 0.84–0.91, confirming excellent intraobserver agreement for PRUDA and UCORA.
Incorrect. The correct answer is Intraclass correlation coefficients > 0.80.
ICC values were 0.84–0.91, confirming excellent intraobserver agreement for PRUDA and UCORA.

🔍 Key Findings

  • PRUDA (proximal radio-ulnar divergence angle) and UCORA (ulnar center of rotation of angulation) were significantly greater in Cocker Spaniels with HIF vs those without.
  • PRUDA (p < .001): Group 1 (HIF) vs Group 2 & 3.
  • UCORA (p = .036): Group 1 vs Group 3.
  • Other angles (MPRA, LDRA, PCRA, DCRA, torsion) showed no significant differences.
  • Increased PRUDA and UCORA may lead to divergent load vectors across the humeral condyle, potentially predisposing to stress fracture (HIF).
  • Measurement techniques using CT-based 3D reconstructions were reliable (intraobserver ICC > 0.84).

Burton

Veterinary Surgery

4

2025

Antebrachial conformation in Cocker Spaniels with and without humeral intracondylar fissure

2025-4-VS-burton-3

Article Title: Antebrachial conformation in Cocker Spaniels with and without humeral intracondylar fissure

Journal: Veterinary Surgery

In Nash 2024 et al., on esophageal pH monitoring, what percentage of dogs experienced proximal GER events during the recording period?

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Correct. Only 12 of 31 dogs with dual sensors had proximal GER, corresponding to 39%.
Incorrect. The correct answer is 39%.
Only 12 of 31 dogs with dual sensors had proximal GER, corresponding to 39%.

🔍 Key Findings

  • Esophageal pH-monitoring was well tolerated in all 35 nonbrachycephalic dogs, with no major adverse events reported.
  • Distal GER occurred in 80% of dogs, but events were typically brief and non-productive; proximal GER occurred in only 39%.
  • Upper reference limits for GER were 2.4 events/hour (distal) and 0.4 events/hour (proximal).
  • Cumulative acid exposure was minimal: upper limits were 2.3% (distal) and 0% (proximal).
  • Comparison with brachycephalic dogs shows significantly higher GER frequency and duration, validating the diagnostic utility of pH monitoring.
  • Transnasal probe placement under light anesthesia was safe and less morbid compared to percutaneous or conscious techniques.
  • No expelled or productive regurgitation occurred, despite some GER events, indicating efficient esophageal clearance in healthy dogs.
  • Diet and fasting duration may affect GER, but these were not controlled variables in this study.

Nash

Veterinary Surgery

8

2024

Esophageal pH‐monitoring in nonbrachycephalic dogs: A reference

2024-8-VS-nash-4

Article Title: Esophageal pH‐monitoring in nonbrachycephalic dogs: A reference

Journal: Veterinary Surgery

In Townsend 2024 et al., on 3D osteotomy accuracy, which of the following planes showed significant improvement with PSG in both simple and complex cuts?

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Correct. Frontal plane improved in both simple and complex cuts; sagittal improved in complex cuts (Group 3).
Incorrect. The correct answer is Frontal and sagittal.
Frontal plane improved in both simple and complex cuts; sagittal improved in complex cuts (Group 3).

🔍 Key Findings:

  • Design: Ex vivo study with 24 paired limbs from normal beagle dogs.
  • Osteotomy types (3 groups):
    1. 30° uniplanar frontal wedge
    2. Oblique (30° frontal, 15° sagittal)
    3. Single oblique (30° frontal, 15° sagittal, 30° external rotation)
  • Comparison: 3D PSG vs Freehand (FH)
  • Main Outcomes:
    • PSG accuracy: Mean angular deviation = 2.8° vs 6.4° in FH (p < .001).
    • 84% of PSG osteotomies were within 5° of target vs 50% of FH.
  • Significant improvements with PSG in:
    • Group 1 (uniplanar frontal) proximal and distal frontal planes (p < .001, .006)
    • Group 3 (SOO) frontal and sagittal planes (p = .002, .043)
  • Time: PSG faster in complex SOO group (84s vs 162s, p < .001); no difference in others.
  • No difference in osteotomy location (mm) between methods.
  • Clinical relevance: PSG more consistent and accurate, especially for complex cuts.

Townsend

Veterinary Surgery

2

2024

Comparison of three-dimensional printed patient-specific guides versus freehand approach for radial osteotomies in normal dogs: Ex vivo model

2024-2-VS-townsend-4

Article Title: Comparison of three-dimensional printed patient-specific guides versus freehand approach for radial osteotomies in normal dogs: Ex vivo model

Journal: Veterinary Surgery

In Paulick 2022 et al., on feline ilial plating, which of the following statements best describes the failure mode observed in **locking plate constructs**?

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Correct. Locking constructs consistently failed via bone slicing, not screw loosening.
Incorrect. The correct answer is Bone slicing occurred in all specimens.
Locking constructs consistently failed via bone slicing, not screw loosening.

🔍 Key Findings

  • Locking plates (except ALPS-5) withstood significantly more cycles before failure than nonlocking DCP constructs.
  • ALPS-6.5, LCP, and FIXIN plates endured higher loads and resisted displacement better than DCP and ALPS-5.
  • ALPS-5 plates showed lower bending stiffness than all other constructs (P < .05).
  • DCP constructs failed due to screw loosening, seen in all specimens.
  • Locking constructs failed by bone slicing, affecting 100% of specimens.
  • Catastrophic implant failure (fracture or plastic deformation) occurred only in ALPS-5 group.
  • Plate size and screw-plate interface both influence resistance to cyclic loading in feline ilial fracture repair.
  • Locking plates are preferable for reducing screw pullout, but plate strength (e.g., cross-section) must match loading forces.

Paulick

Veterinary Surgery

1

2022

Ex vivo comparison of lateral plate repairs of experimental oblique ilial fractures in cats

2022-1-VS-paulick-4

Article Title: Ex vivo comparison of lateral plate repairs of experimental oblique ilial fractures in cats

Journal: Veterinary Surgery

In Bounds 2023 et al., on feline hip arthroscopy, which statement best describes feasibility of hip arthroscopy in cats with DJD?

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Correct. The two DJD hips showed no difference in arthroscopic access or visibility.
Incorrect. The correct answer is Feasible with comparable visualization to normal hips.
The two DJD hips showed no difference in arthroscopic access or visibility.

🔍 Key Findings

  • Feline hip arthroscopy using a supratrochanteric lateral portal was feasible in all cadaveric hips studied.
  • All relevant intra-articular structures (femoral head, acetabulum, round ligament, joint capsule, transverse acetabular ligament, dorsal acetabular rim) were consistently visualized.
  • Optimal limb positioning (neutral abduction, 90° extension) significantly aided joint distraction and visualization.
  • Minor iatrogenic cartilage injury (ICI) occurred in all hips, typically partial-thickness abrasions; one hip had a full-thickness lesion.
  • Portal placement did not damage the sciatic nerve or caudal gluteal artery, with a mean distance of 4.3 ± 2 mm between the cannula and nerve.
  • Probe use improved visualization of the dorsal joint capsule and dorsal acetabular rim, though not essential.
  • Joint evaluation was also successful in hips with DJD, suggesting technique feasibility even in diseased joints.
  • Muscle trauma was minimal, with only mild impingement in a few specimens and no gross nerve or vessel injury.

Bounds

Veterinary Surgery

8

2023

Feasibility of feline coxofemoral arthroscopy using a supratrochanteric lateral portal: A cadaveric study

2023-8-VS-bounds-5

Article Title: Feasibility of feline coxofemoral arthroscopy using a supratrochanteric lateral portal: A cadaveric study

Journal: Veterinary Surgery

In Kimura 2025 et al., on mini-THA in <4 kg dogs, which implant strategy was used to reduce risk of femoral fracture during THA in small dogs?

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Correct. Prophylactic screws and plates were used in cases with instability or over-reaming to prevent fracture:contentReference[oaicite:4]{index=4}.
Incorrect. The correct answer is Use of prophylactic bicortical screw and plate.
Prophylactic screws and plates were used in cases with instability or over-reaming to prevent fracture:contentReference[oaicite:4]{index=4}.

🔍 Key Findings

  • Zurich mini-cementless THA was successful in 9/10 hips in dogs <4 kg, with no lameness at 52 weeks in completed cases.
  • Helsinki Chronic Pain Index significantly improved from a mean of 19.8 to 2.3 at 52 weeks (p = 0.0141).
  • Fluoroscopy improved implant positioning, especially in LCPD and HD cases, aiding in accurate reaming and alignment.
  • Intraoperative complications occurred in 2/10 cases, including acetabular fractures; one case required discontinuation.
  • Prophylactic bicortical screws and reinforcement plates were used in cases with rotational instability or cortical compromise and were effective in preventing loosening/fractures.
  • Medial patellar luxation improved postoperatively in one dog, though recurrence was noted later without surgical correction.
  • No stem or implant loosening or fracture occurred over a mean follow-up of 24.4 months.
  • CT is recommended in preoperative planning, particularly in luxoid hip dysplasia cases with uncertain bone stock.

Kimura

Veterinary Surgery

6

2025

Long‐term outcomes of 10 dogs weighing less than 4 kg after Zurich mini‐cementless total hip arthroplasty

2025-6-VS-kimura-5

Article Title: Long‐term outcomes of 10 dogs weighing less than 4 kg after Zurich mini‐cementless total hip arthroplasty

Journal: Veterinary Surgery

Quiz Results

Previously Missed Questions
70%

You answered 7 out of 10 questions correctly

Question 1:

❌ Incorrect. You answered: Answer

Correct answer:

Rationale

Question 1:

✅ Correct! You answered: Answer

Rationale

Author: Journal Name - 2025

Article Title

Key Findings

Something off with this question?
Tell us what needs fixing—drop your note below.

You’re flagging: [question text]

Thanks for your feedback!
We’ll review your comment as soon as possible.
Oops! Something went wrong while submitting the form.