
Your Custom Quiz
In Neal 2023 et al., on transcondylar screw placement, which variable significantly influenced screw trajectory deviation regardless of method used?
🔍 Key Findings
- Aiming device provided comparable trajectory accuracy to fluoroscopy, especially in right limbs (1.9° vs. 3.4°, p = .0128).
- Eccentricity (deviation from condylar center) was lower with fluoroscopy (3.1 mm vs 4.2 mm, p = .0017), making fluoroscopy more precise.
- Odds of joint infringement were 8× higher with the aiming device, though not statistically significant (p = .0575).
- Residents had greater screw trajectory deviation than diplomates (p = .0366), highlighting impact of experience.
- Aiming device procedures took less time than fluoroscopy in some scenarios, particularly for right limbs with right-handed surgeons.
- Fluoroscopic procedures had more pin/drill attempts, increasing risk of glove puncture and potential aseptic breaks.
- Mean deviation angles in both groups (<3.5°) were within acceptable range to avoid intracondylar fracture gap.
- Cadaver model used large-breed, healthy adult dogs, not small-breed immature dogs, limiting generalizability.
Veterinary Surgery
4
2023
The effect of an aiming device on the accuracy of humeral transcondylar screw placement
2023-4-VS-neal-4
In Cola 2024 et al., on laparotomy-assisted endoscopy, which of the following foreign body characteristics significantly affected the success of LAER?
🔍 Key Findings
- LAER was effective (partial or complete) in 35/40 cases, regardless of FB location or type.
- Intestinal wall damage significantly increased the likelihood of conversion to enterotomy (p = .043).
- LAER led to significantly shorter hospitalization (median 48 h vs 72 h; p = .006).
- Patients in the LAER group required less postoperative analgesia (median 36 h vs 48 h; p < .001).
- Faster return to spontaneous feeding was seen in LAER group (median 24 h vs 36 h; p = .012).
- No significant difference in complication rate or postoperative ileus between LAER and enterotomy groups.
- Sharp, linear, or multiple FBs did not significantly affect LAER effectiveness.
- Conversion to surgery was required in 5/40 LAER attempts, mostly due to immovable FBs or intestinal damage.
Veterinary Surgery
7
2024
Laparotomy‐assisted endoscopic removal of gastrointestinal foreign bodies: Evaluation of this technique and postoperative recovery in dogs and cats
2024-7-VS-cola-5
In Ritson 2025 et al., on feline hilar lobectomy sealants, how were devices evaluated for seal integrity?
🔍 Key Findings
- No leakage occurred using pretied ligature loops (PLL) or double-shank (DS) titanium clips up to 40 cm H₂O airway pressure.
- 1/10 stapled lobes leaked at supraphysiologic pressure (40 cm H₂O), but this was not statistically significant (p = .33).
- All techniques sealed effectively under physiologic and supraphysiologic pressures in cadaveric feline lungs.
- PLL and DS clips required less working space than staplers, making them more practical for small thoracic cavities.
- DS titanium clips offer enhanced security due to dual shanks and tissue-gripping design, reducing clip slippage.
- Leak testing was cyclic and submerged, simulating physiologic ventilation and allowing robust evaluation.
- Stapling failure occurred along the staple line, highlighting risks of air leakage due to staple misalignment or poor hilar access.
- PLL and DS clips may be cost-effective and efficient alternatives for open or minimally invasive feline lung lobectomy.
Veterinary Surgery
7
2025
Ex vivo comparative evaluation of feline hilar lung lobectomy using linear stapler, pretied ligature loop, and double-shank titanium clips
2025-7-VS-ritson-4
In Longo 2025 et al., on MITA, what percentage of dogs achieved complete osseous union?
🔍 Key Findings
- 15 dogs underwent minimally invasive tarsal arthrodesis (MITA); 10 partial, 5 pantarsal.
- Mean time to radiographic union: 1.8 ± 0.5 months.
- Mean time to clinical union: 3.7 ± 0.8 months.
- Complete osseous union: 46%; the rest achieved ≥50% with functional weightbearing.
- Complication rate: 26% major (mostly implant-related); no catastrophic complications or plantar necrosis.
- Functional outcomes: 6 full, 8 acceptable, 1 unacceptable (not due to MITA).
- MITA may lower soft tissue complications vs open approaches and enable faster healing.
Veterinary Surgery
1
2025
Minimally invasive tarsal arthrodesis in 15 dogs
2025-1-VS-longo-2
In Burton 2025 et al., on antebrachial conformation, what statistical result supported intraobserver reliability of PRUDA and UCORA?
🔍 Key Findings
- PRUDA (proximal radio-ulnar divergence angle) and UCORA (ulnar center of rotation of angulation) were significantly greater in Cocker Spaniels with HIF vs those without.
- PRUDA (p < .001): Group 1 (HIF) vs Group 2 & 3.
- UCORA (p = .036): Group 1 vs Group 3.
- Other angles (MPRA, LDRA, PCRA, DCRA, torsion) showed no significant differences.
- Increased PRUDA and UCORA may lead to divergent load vectors across the humeral condyle, potentially predisposing to stress fracture (HIF).
- Measurement techniques using CT-based 3D reconstructions were reliable (intraobserver ICC > 0.84).
Veterinary Surgery
4
2025
Antebrachial conformation in Cocker Spaniels with and without humeral intracondylar fissure
2025-4-VS-burton-3
In Nash 2024 et al., on esophageal pH monitoring, what percentage of dogs experienced proximal GER events during the recording period?
🔍 Key Findings
- Esophageal pH-monitoring was well tolerated in all 35 nonbrachycephalic dogs, with no major adverse events reported.
- Distal GER occurred in 80% of dogs, but events were typically brief and non-productive; proximal GER occurred in only 39%.
- Upper reference limits for GER were 2.4 events/hour (distal) and 0.4 events/hour (proximal).
- Cumulative acid exposure was minimal: upper limits were 2.3% (distal) and 0% (proximal).
- Comparison with brachycephalic dogs shows significantly higher GER frequency and duration, validating the diagnostic utility of pH monitoring.
- Transnasal probe placement under light anesthesia was safe and less morbid compared to percutaneous or conscious techniques.
- No expelled or productive regurgitation occurred, despite some GER events, indicating efficient esophageal clearance in healthy dogs.
- Diet and fasting duration may affect GER, but these were not controlled variables in this study.
Veterinary Surgery
8
2024
Esophageal pH‐monitoring in nonbrachycephalic dogs: A reference
2024-8-VS-nash-4
In Townsend 2024 et al., on 3D osteotomy accuracy, which of the following planes showed significant improvement with PSG in both simple and complex cuts?
🔍 Key Findings:
- Design: Ex vivo study with 24 paired limbs from normal beagle dogs.
- Osteotomy types (3 groups):
- 30° uniplanar frontal wedge
- Oblique (30° frontal, 15° sagittal)
- Single oblique (30° frontal, 15° sagittal, 30° external rotation)
- Comparison: 3D PSG vs Freehand (FH)
- Main Outcomes:
- PSG accuracy: Mean angular deviation = 2.8° vs 6.4° in FH (p < .001).
- 84% of PSG osteotomies were within 5° of target vs 50% of FH.
- Significant improvements with PSG in:
- Group 1 (uniplanar frontal) proximal and distal frontal planes (p < .001, .006)
- Group 3 (SOO) frontal and sagittal planes (p = .002, .043)
- Time: PSG faster in complex SOO group (84s vs 162s, p < .001); no difference in others.
- No difference in osteotomy location (mm) between methods.
- Clinical relevance: PSG more consistent and accurate, especially for complex cuts.
Veterinary Surgery
2
2024
Comparison of three-dimensional printed patient-specific guides versus freehand approach for radial osteotomies in normal dogs: Ex vivo model
2024-2-VS-townsend-4
In Paulick 2022 et al., on feline ilial plating, which of the following statements best describes the failure mode observed in **locking plate constructs**?
🔍 Key Findings
- Locking plates (except ALPS-5) withstood significantly more cycles before failure than nonlocking DCP constructs.
- ALPS-6.5, LCP, and FIXIN plates endured higher loads and resisted displacement better than DCP and ALPS-5.
- ALPS-5 plates showed lower bending stiffness than all other constructs (P < .05).
- DCP constructs failed due to screw loosening, seen in all specimens.
- Locking constructs failed by bone slicing, affecting 100% of specimens.
- Catastrophic implant failure (fracture or plastic deformation) occurred only in ALPS-5 group.
- Plate size and screw-plate interface both influence resistance to cyclic loading in feline ilial fracture repair.
- Locking plates are preferable for reducing screw pullout, but plate strength (e.g., cross-section) must match loading forces.
Veterinary Surgery
1
2022
Ex vivo comparison of lateral plate repairs of experimental oblique ilial fractures in cats
2022-1-VS-paulick-4
In Bounds 2023 et al., on feline hip arthroscopy, which statement best describes feasibility of hip arthroscopy in cats with DJD?
🔍 Key Findings
- Feline hip arthroscopy using a supratrochanteric lateral portal was feasible in all cadaveric hips studied.
- All relevant intra-articular structures (femoral head, acetabulum, round ligament, joint capsule, transverse acetabular ligament, dorsal acetabular rim) were consistently visualized.
- Optimal limb positioning (neutral abduction, 90° extension) significantly aided joint distraction and visualization.
- Minor iatrogenic cartilage injury (ICI) occurred in all hips, typically partial-thickness abrasions; one hip had a full-thickness lesion.
- Portal placement did not damage the sciatic nerve or caudal gluteal artery, with a mean distance of 4.3 ± 2 mm between the cannula and nerve.
- Probe use improved visualization of the dorsal joint capsule and dorsal acetabular rim, though not essential.
- Joint evaluation was also successful in hips with DJD, suggesting technique feasibility even in diseased joints.
- Muscle trauma was minimal, with only mild impingement in a few specimens and no gross nerve or vessel injury.
Veterinary Surgery
8
2023
Feasibility of feline coxofemoral arthroscopy using a supratrochanteric lateral portal: A cadaveric study
2023-8-VS-bounds-5
In Kimura 2025 et al., on mini-THA in <4 kg dogs, which implant strategy was used to reduce risk of femoral fracture during THA in small dogs?
🔍 Key Findings
- Zurich mini-cementless THA was successful in 9/10 hips in dogs <4 kg, with no lameness at 52 weeks in completed cases.
- Helsinki Chronic Pain Index significantly improved from a mean of 19.8 to 2.3 at 52 weeks (p = 0.0141).
- Fluoroscopy improved implant positioning, especially in LCPD and HD cases, aiding in accurate reaming and alignment.
- Intraoperative complications occurred in 2/10 cases, including acetabular fractures; one case required discontinuation.
- Prophylactic bicortical screws and reinforcement plates were used in cases with rotational instability or cortical compromise and were effective in preventing loosening/fractures.
- Medial patellar luxation improved postoperatively in one dog, though recurrence was noted later without surgical correction.
- No stem or implant loosening or fracture occurred over a mean follow-up of 24.4 months.
- CT is recommended in preoperative planning, particularly in luxoid hip dysplasia cases with uncertain bone stock.
Veterinary Surgery
6
2025
Long‐term outcomes of 10 dogs weighing less than 4 kg after Zurich mini‐cementless total hip arthroplasty
2025-6-VS-kimura-5
Quiz Results
You answered 7 out of 10 questions correctly
Key Findings
