
Your Custom Quiz
In Fink 2025 et al., on Roux-en-Y outcomes, what was the reported overall postoperative mortality rate?
🔍 Key Findings
- Roux-en-Y procedures were successfully completed in all 11 cases (6 dogs, 5 cats), despite case complexity and disease severity.
- Median survival post-discharge was longer in cats (365 days) vs. dogs (82 days), with better outcomes in non-neoplastic vs. neoplastic disease (192 vs. 5 days).
- Complication rate was high, with septic peritonitis, dehiscence, and cardiac arrest as leading causes of postoperative death; mortality rate = 36%.
- Dehiscence rate was 8.6% (2 of 23 anastomoses), considered lower than typical rates for GI anastomoses in high-risk patients.
- Feeding tubes (gastrostomy/jejunostomy) were used in all cases, enabling early nutritional support and stomach decompression.
- Postoperative nausea and vomiting were common but mostly self-limiting; managed with metoclopramide, cisapride, and antiemetics.
- Choledochojejunostomy was preferred when common bile duct was dilated, offering a favorable size match and potentially reducing bile leakage.
- Roux-en-Y reduced typical Billroth II complications (e.g., bile reflux, afferent loop syndrome, dumping syndrome), with none observed in discharged patients.
Veterinary Surgery
5
2025
Roux‐en‐Y procedure to reconstruct the upper gastrointestinal tract in six dogs and five cats: A descriptive case series
2025-5-VS-fink-1
In Hertel 2025 et al., on portal venotomy for insulinoma, what was the duration of portal vein occlusion tolerated during surgery?
🔍 Key Findings
- Portal venotomy enabled successful en bloc resection of a pancreatic insulinoma and associated thrombus in the portal vein, a novel approach in veterinary literature.
- Temporary portal vein occlusion (15 min) was well tolerated, causing only transient small intestinal congestion without lasting hemodynamic compromise.
- No intraoperative hemorrhage occurred following vascular isolation and venotomy repair with 5–0 polypropylene in a simple continuous pattern.
- Postoperative complications were minimal, with only moderate pancreatitis managed medically and no portal hypertension observed on follow-up imaging.
- Histopathology confirmed insulinoma, with no initial metastasis; CT at 6 months revealed hepatic and peritoneal metastases but no local recurrence at the venotomy site.
- Portal vein luminal stenosis occurred post-repair but was clinically insignificant.
- Advanced CT imaging and 3D printed modeling significantly enhanced surgical planning and anatomical assessment.
- Surgical excision achieved good short-term outcomes, and the dog was alive and euglycemic one year later despite metastatic disease.
Veterinary Surgery
5
2025
Successful venotomy for portal tumor thrombus removal due to pancreatic carcinoma in a dog
2025-5-VS-hertel-2
In Kuvaldina 2023 et al., on axillary lymph node excision, which of the following tools was essential for minimally invasive access to the axillary region?
🔍 Key Findings
- Endoscopic excisional biopsy of axillary lymph nodes was successfully performed in cadavers and clinical dogs with minimal complications.
- The technique used a SILS port and CO₂ insufflation through a small incision between the latissimus dorsi and superficial pectorals.
- In 4 cadavers (6 limbs), mean time to remove axillary nodes was 33 minutes, and single nodes were found in 5/6 limbs.
- In 3 clinical dogs, the procedure was successful in 2 cases; 1 required conversion to open surgery due to difficulty manipulating the node.
- Accessory axillary nodes were successfully excised when present, located adherent to deep latissimus dorsi.
- No cases developed lymphedema, pneumothorax, or major complications postoperatively.
- Subjective benefits included better visualization, reduced dissection, and less postoperative morbidity than open techniques.
- Study suggests MIS lymphadenectomy may improve staging accuracy and reduce complications, though larger studies are needed.
Veterinary Surgery
6
2023
Development of a minimally invasive endoscopic technique for excisional biopsy of the axillary lymph nodes in dogs
2023-6-VS-kuvaldina-1
In Nash 2024 et al., on monitoring technique, what best describes the esophageal pH probe placement method?
🔍 Key Findings Summary
- Population: 35 nonbrachycephalic dogs undergoing orthopedic procedures (TPLO)
- Study design: Prospective observational using transnasal Digitrapper dual-sensor pH probe after short TIVA
- Upper reference limits:
- Distal GER events per hour: 2.4
- Proximal GER events per hour: 0.4
- Cumulative distal acid exposure: 2.3%
- Cumulative proximal acid exposure: 0%
- Median values (normal):
- Distal GER events per hour: 0.3
- Proximal GER events per hour: 0
- Proximal GER observed in 12/31 dogs
- No regurgitation observed in any dog
- No major adverse events with probe use
- Clinical implication: These parameters provide a reference for assessing excessive GER in future canine surgical cases
Veterinary Surgery
1
2024
Esophageal pH‐monitoring in nonbrachycephalic dogs; a reference
2024-1-VS-nash-3
In Huels 2025 et al., on second-generation screw cup THA, what was the primary functional outcome observed in dogs following SCSL THA?
🔍 Key Findings
- Total complication rate was 16.7%, with 5/30 hips experiencing major complications, mostly related to the femoral component.
- Cup-associated complications were rare (3.3%), with only one case of acetabular cup luxation attributed to surgical technique rather than implant failure.
- No cases of late aseptic loosening were observed during a median follow-up of 17.5 months.
- Implant stability was attributed to the SCSL's porous, trabecular titanium surface, enhancing osseointegration.
- Three femoral stem fractures occurred in a single dog, leading to implant removal; material testing was not performed.
- Most complications were femoral in origin (6/7), not acetabular, suggesting improved performance of the SCSL.
- Explantation rate was 13% (4/30), but some removals were due to owner preference against revision.
- Subjective functional outcome was full recovery in 26/30 hips, including one with successful revision of stem subsidence.
Veterinary and Comparative Orthopaedics and Traumatology
2
2025
Complications and Long-Term Outcome in 30 Canine Total Hip Arthroplasties Using a Second-Generation Selective Laser Melted Screw Cup
2025-2-VCOT-huels-5
In Evers 2022 et al., on bone-to-tendon plate fixation, what fixation technique was used to secure the plate to the tendon?
🔍 Key Findings
- Bone-to-tendon plate fixation allowed successful stabilization of a highly comminuted calcaneus fracture in a dog with fragments too small for traditional fixation.
- The plate was sutured to the common calcaneal tendon using a figure-of-8 pattern, bypassing the need for screw fixation into small proximal fragments.
- Radiographic union was achieved by 17 weeks, though considered delayed, with the dog returning to normal function by 36 weeks post-op.
- A second surgery was required to replace the tendon-anchored plate with a calcaneus-only plate due to skin ulceration and implant prominence.
- Implant-associated infection was suspected; cultures confirmed Staphylococcus pseudintermedius, managed with doxycycline and clindamycin.
- Use of human placental matrix (hPM) and both autogenous and allogenic bone grafts supported healing, though their specific contribution remains uncertain.
- Postoperative complications included delayed union and skin ulceration, emphasizing challenges of implant design and soft tissue management.
- This is the first report of using a bone-to-tendon plate for a calcaneus fracture in dogs and demonstrates its potential in cases where traditional methods are not viable.
Veterinary Surgery
5
2022
Use of a bone‐to‐tendon plate to stabilize a comminuted calcaneus fracture in a dog
2022-5-VS-evers-4
In Cortez 2024 et al., on feline ectopic ureters, which surgical technique was used most frequently?
🔍 Key Findings
- Ectopic ureters in cats are rare, but most are extramural and bilateral.
- Surgical techniques used included ureteroneocystostomy (UNC), neoureterostomy (NU), nephroureterectomy, and cystoscopic laser ablation (CLA).
- All cats showed improvement in urinary continence postoperatively, with 11/12 achieving complete resolution.
- Major complications were rare; one cat developed uroabdomen requiring revision surgery.
- Diagnostic imaging was effective, with abdominal ultrasound diagnosing 8/10 and CT 3/3 cases.
- Short- and long-term complications included urethral spasms, UTIs, stranguria, and rectal prolapse; all were manageable.
- CLA was successful in 2 cats and is noted as a first-time described technique in feline ectopic ureter cases.
- Median postoperative follow-up was 340 days, supporting good long-term outcomes.
Veterinary Surgery
6
2024
Presentation, diagnosis, and outcomes of cats undergoing surgical treatment of ectopic ureters
2024-6-VS-cortez-1
In Trefny 2025 et al., on plate length and stiffness, which biomechanical testing method was used to measure stiffness and strain?
🔍 Key Findings
- 12-hole LCPs (80% plate–bone ratio) showed significantly higher construct stiffness than 6-, 8-, or 10-hole plates in both compression and tension bending.
- Strain on the plate was significantly lower in 12-hole vs 6-hole plates at all regions of interest (ROIs), especially around the fracture gap.
- No incremental increases in stiffness or decreases in strain were observed between 6-, 8-, and 10-hole plates—only when comparing to 12-hole plates.
- Bone model strain adjacent to the plate end was significantly lower for 10- and 12-hole plates vs 6-hole plates under both loading conditions.
- The threshold effect suggests biomechanical benefits only emerge beyond a plate–bone ratio of ~80%.
- Working length increased from 9.4 mm (6-hole) to 13 mm (others), potentially influencing strain/stiffness differences.
- Four-point bending was used, as it replicates the most biomechanically relevant force on plated long bones.
- Clinical implication: Longer plates may reduce plate strain and peri-implant bone strain, potentially lowering risk of fatigue failure or stress risers.
Veterinary and Comparative Orthopaedics and Traumatology
2
2025
Effect of Plate Length on Construct Stiffness and Strain in a Synthetic Short-Fragment Fracture Gap Model Stabilized with a 3.5-mm Locking Compression Plate
2025-2-VCOT-trefny-4
In Burkhardt 2024 et al., on coagulation testing in liver lobectomy, dogs with both PT and aPTT prolongation were how much more likely to undergo emergency surgery?
🔍 Key Findings
- 20.6% of dogs had a preoperative prolongation in PT or aPTT, but only 5.6% had both prolonged.
- Hemangiosarcoma was the only tumor type significantly associated with both PT and aPTT prolongation (37.5% of hemangiosarcoma cases, p < .001).
- Dogs with both PT and aPTT prolongations were 6.5× more likely to have emergency surgery (p < .001) and 2.5× more likely to have hemoabdomen (p = .0022).
- 60% of dogs with both PT and aPTT prolongation required blood transfusion (p < .001).
- Only 1.9% of all dogs had both PT and aPTT prolonged by >25%, suggesting limited clinical utility of routine PT/aPTT testing.
- Platelet count <50,000/μL was rare (1.5%) and not associated with PT/aPTT changes or transfusions.
- Routine PT/aPTT testing offers low diagnostic yield in elective liver lobectomy cases.
- Authors recommend case-by-case PT/aPTT screening, especially when hemangiosarcoma or bleeding tendencies are suspected.
Veterinary Surgery
7
2024
Evaluating preoperative coagulation panels in dogs undergoing liver lobectomy for primary liver tumors: A multi-institutional retrospective study
2024-7-VS-burkhardt-3
In Ritson 2025 et al., on feline hilar lobectomy sealants, how were devices evaluated for seal integrity?
🔍 Key Findings
- No leakage occurred using pretied ligature loops (PLL) or double-shank (DS) titanium clips up to 40 cm H₂O airway pressure.
- 1/10 stapled lobes leaked at supraphysiologic pressure (40 cm H₂O), but this was not statistically significant (p = .33).
- All techniques sealed effectively under physiologic and supraphysiologic pressures in cadaveric feline lungs.
- PLL and DS clips required less working space than staplers, making them more practical for small thoracic cavities.
- DS titanium clips offer enhanced security due to dual shanks and tissue-gripping design, reducing clip slippage.
- Leak testing was cyclic and submerged, simulating physiologic ventilation and allowing robust evaluation.
- Stapling failure occurred along the staple line, highlighting risks of air leakage due to staple misalignment or poor hilar access.
- PLL and DS clips may be cost-effective and efficient alternatives for open or minimally invasive feline lung lobectomy.
Veterinary Surgery
7
2025
Ex vivo comparative evaluation of feline hilar lung lobectomy using linear stapler, pretied ligature loop, and double-shank titanium clips
2025-7-VS-ritson-4
Quiz Results
You answered 7 out of 10 questions correctly
Key Findings
